Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Trop Med Infect Dis ; 8(12)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38133450

RESUMO

Migratory flows and international travel are triggering an increase in imported cases of schistosomiasis in non-endemic countries. The present study aims to evaluate the effectiveness of the LAMP technique on patients' urine samples for the diagnosis of imported schistosomiasis in a non-endemic area in comparison to a commercial immunochromatographic test and microscopic examination of feces and urine. A prospective observational study was conducted in sub-Saharan migrants attending the Tropical Medicine Unit, Almería, Spain. For schistosomiasis diagnosis, serum samples were tested using an immunochromatographic test (Schistosoma ICT IgG-IgM). Stool and urine samples were examined by microcopy. Urine samples were evaluated by combining three LAMP assays for the specific detection of Schistosoma mansoni, S. haematobium, and for the genus Schistosoma. To evaluate the diagnostic accuracy, a latent class analysis (LCA) was performed. In total, 115 patients were included (92.2% male; median age: 28.3 years). Of these, 21 patients (18.3%) were diagnosed with schistosomiasis confirmed by microscopy, with S. haematobium being the most frequent species identified (18/115; 15.7%). The Schistosoma ICT IgG-IgM test result was 100% positive and Schistosoma-LAMP was 61.9% positive, reaching as high as 72.2% for S. haematobium. The sensitivity and specificity estimated by LCA, respectively, were: 92% and 76% for Schistosoma ICT IgG-IgM, 68% and 44% for Schistosoma-LAMP, and 46% and 97% for microscopy. In conclusion, the Schistosoma-LAMP technique presented a higher sensitivity than microscopy for the diagnosis of imported urinary schistosomiasis, which could improve the diagnosis of active infection, both in referral centers and in centers with limited experience or scarce resources and infrastructure.

2.
Parasit Vectors ; 16(1): 393, 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37907997

RESUMO

BACKGROUND: Strongyloides stercoralis infection is a common neglected tropical disease distributed worldwide, mainly in tropical and subtropical climates. The impact of S. stercoralis infections on human health ranges from mild asymptomatic infections to chronic strongyloidiasis unnoticeable until the host is immunosuppressed. In severe strongyloidiasis, a syndrome of hyperinfection and larval dissemination to various organs can occur with high mortality rates. The diagnosis of strongyloidiasis is challenging because of the absence of a single standard reference test with high sensitivity and specificity, which also makes it difficult to estimate the accuracy of other diagnostic tests. This study aimed to evaluate, for the first time, the use of an easy-to-perform loop-mediated isothermal amplification (LAMP) colorimetric assay (named Strong-LAMP) for the molecular screening of strongyloidiasis in stool samples from patients in a low-resource endemic area in Cubal, Angola. To compare different LAMP application scenarios, the performance of the Strong-LAMP under field conditions in Angola was reassessed in a well-equipped reference laboratory in Spain and compared with a quantitative polymerase chain reaction (qPCR) method. METHODS: A total of 192 stool samples were collected from adult population in Cubal, Angola, and examined by parasitological methods (direct saline microscopy and Baermann's technique). DNA was extracted from each stool sample using a commercial kit and tested by the colorimetric Strong-LAMP assay for the detection of Strongyloides spp. under field conditions. Furthermore, all samples were shipped to a well-equipped laboratory in Spain, reanalysed by the same procedure and compared with a qPCR method. The overall results after testing were compared. RESULTS: Strongyloides stercoralis larvae were identified by direct saline microscopy and Baermann in a total of 10/192 (5.2%) and 18/192 (9.4%) stool samples, respectively. Other helminth and protozoan species were also identified. The Strong-LAMP-positive results were visually detected in 69/192 (35.9%) stool samples. The comparison of Strong-LAMP results in field conditions and at a reference laboratory matched in a total of 146/192 (76.0%) samples. A total of 24/192 (12.5%) stool samples tested positive by qPCR. CONCLUSIONS: This is the first study in which colorimetric Strong-LAMP has been clinically evaluated in a resource-poor strongyloidiasis endemic area. Strong-LAMP has been shown to be more effective in screening for strongyloidiasis than parasitological methods under field conditions and qPCR in the laboratory. Our Strong-LAMP has proven to be a field-friendly and highly accurate molecular test for the diagnosis of strongyloidiasis.


Assuntos
Strongyloides stercoralis , Estrongiloidíase , Adulto , Animais , Humanos , Estrongiloidíase/diagnóstico , Estrongiloidíase/epidemiologia , Angola , Strongyloides stercoralis/genética , Laboratórios , Fezes
3.
Am J Trop Med Hyg ; 109(6): 1368-1371, 2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-37931298

RESUMO

Onchocerciasis has been declared eliminated in Ecuador and surveillance measures are of great interest. In this study, we examined the infectivity rates of Simulium exiguum by Onchocerca volvulus in previously hyperendemic areas in Esmeraldas province of Ecuador. These areas had previously undergone mass administration of ivermectin, which led to the interruption of transmission in 2009 and the certification of elimination in 2014. The study included three communities in Río Cayapas and one in Río Canandé, and a total of 2,950 adult S. exiguum were collected in 2018. We used quantitative polymerase chain reaction with O. volvulus O-150 plasmid control DNA to analyze 59 pools. Our findings revealed that the infectivity rates were zero, indicating that the transmission of O. volvulus remained suspended in the area.


Assuntos
Volvo Intestinal , Onchocerca volvulus , Oncocercose , Simuliidae , Humanos , Animais , Adulto , Oncocercose/diagnóstico , Oncocercose/epidemiologia , Oncocercose/prevenção & controle , Onchocerca volvulus/genética , Reação em Cadeia da Polimerase em Tempo Real , Equador/epidemiologia , Ivermectina/uso terapêutico , Onchocerca/genética
4.
Infect Dis Poverty ; 12(1): 95, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37845734

RESUMO

BACKGROUND: The complexity of the Chagas disease and its phases is impossible to have a unique test for both phases and a lot of different epidemiological scenarios. Currently, serology is the reference standard technique; occasionally, results are inconclusive, and a different diagnostic technique is needed. Some guidelines recommend molecular testing. A systematic review and meta-analysis of available molecular tools/techniques for the diagnosis of Chagas disease was performed to measure their heterogeneity and efficacy in detecting Trypanosoma cruzi infection in blood samples. METHODS: A systematic review was conducted up to July 27, 2022, including studies published in international databases. Inclusion and exclusion criteria were defined to select eligible studies. Data were extracted and presented according to PRISMA 2020 guidelines. Study quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). A random-effects model was used to calculate pooled sensitivity, specificity, and diagnostic odds ratio (DOR). Forest plots and a summary of the receiving operating characteristics (SROC) curves displayed the outcomes. Heterogeneity was determined by I2 and Tau2 statistics and P values. Funnel plots and Deek's test were used to assess publication bias. A quantitative meta-analysis of the different outcomes in the two different clinical phases was performed. RESULTS: We identified 858 records and selected 32 papers. Studies pertained to endemic countries and nonendemic areas with adult and paediatric populations. The sample sizes ranged from 17 to 708 patients. There were no concerns regarding the risk of bias and applicability of all included studies. A positive and nonsignificant correlation coefficient (S = 0.020; P = 0.992) was obtained in the set of studies that evaluated diagnostic tests in the acute phase population (ACD). A positive and significant correlation coefficient (S = 0.597; P < 0.000) was obtained in the case of studies performed in the chronic phase population (CCD). This resulted in high heterogeneity between studies, with the master mix origin and guanidine addition representing significant sources. INTERPRETATION/CONCLUSIONS AND RELEVANCE: The results described in this meta-analysis (qualitative and quantitative analyses) do not allow the selection of the optimal protocol of molecular method for the study of Trypanosoma cruzi infection in any of its phases, among other reasons due to the complexity of this infection. Continuous analysis and optimization of the different molecular techniques is crucial to implement this efficient diagnosis in endemic areas.


Assuntos
Doença de Chagas , Adulto , Criança , Humanos , Sensibilidade e Especificidade , Doença de Chagas/diagnóstico , Doença de Chagas/epidemiologia
5.
Parasit Vectors ; 16(1): 343, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37789462

RESUMO

BACKGROUND: Malaria is a globally distributed infectious disease. According to the World Health Organization, Angola is one of the six countries that account for over half the global malaria burden in terms of both malaria cases and deaths. Diagnosis of malaria still depends on microscopic examination of thin and thick blood smears and rapid diagnostic tests (RDTs), which often lack analytical and clinical sensitivity. Molecular methods could overcome these disadvantages. The aim of this study was to evaluate, for the first time to our knowledge, the performance of a loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria in an endemic area in Cubal, Angola, and to assess the reproducibility at a reference laboratory. METHODS: A total of 200 blood samples from patients attended at Hospital Nossa Senhora da Paz, Cubal, Angola, were analysed for Plasmodium spp. detection by microscopy, RDTs, and LAMP. LAMP assay was easily performed in a portable heating block, and the results were visualized by a simple colour change. Subsequently, the samples were sent to a reference laboratory in Spain to be reanalysed by the same colorimetric LAMP assay and also in real-time LAMP format. RESULTS: In field tests, a total of 67/200 (33.5%) blood samples were microscopy-positive for Plasmodium spp., 98/200 RDT positive, and 112/200 (56%) LAMP positive. Using microscopy as reference standard, field LAMP detected more microscopy-positive samples than RDTs (66/67; 98% vs. 62/67; 92.5%). When samples were reanalysed at a reference laboratory in Spain using both colorimetric and real-time assays, the overall reproducibility achieved 84.5%. CONCLUSIONS: This is the first study to our knowledge in which LAMP has been clinically evaluated on blood samples in a resource-poor malaria-endemic area. The colorimetric LAMP proved to be more sensitive than microscopy and RDTs for malaria diagnosis in field conditions. Furthermore, LAMP showed an acceptable level of reproducibility in a reference laboratory. The possibility to use LAMP in a real-time format in a portable device reinforces the reliability of the assay for molecular diagnosis of malaria in resource-poor laboratories in endemic areas.


Assuntos
Malária Falciparum , Malária , Plasmodium , Humanos , Reprodutibilidade dos Testes , Angola , Laboratórios , Sensibilidade e Especificidade , Malária/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Malária Falciparum/diagnóstico
6.
Artigo em Inglês | IBECS | ID: ibc-226410

RESUMO

Schistosomiasis is a highly prevalent disease, especially in immigrant populations, and is associated with significant morbidity and diagnostic delays outside endemic areas. For these reasons, the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) and the Spanish Society of Tropical Medicine and International Health (SEMTSI) have developed a joint consensus document to serve as a guide for the screening, diagnosis and treatment of this disease outside endemic areas. A panel of experts from both societies identified the main questions to be answered and developed recommendations based on the scientific evidence available at the time. The document was reviewed by the members from both societies for final approval (AU)


La esquistosomiasis es una enfermedad de elevada prevalencia, especialmente en población inmigrante, asociada a importante morbilidad y retraso diagnóstico fuera de zona endémica. Por estas razones, la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC) y la Sociedad Española de Medicina Tropical y Salud Internacional (SEMTSI) han elaborado un documento conjunto de consenso que sirva de guía para el cribado, diagnóstico y tratamiento de esta patología en zonas no endémicas. Un panel de expertos de ambas sociedades identificó las principales preguntas a responder y elaboró las recomendaciones siguiendo la evidencia científica disponible en el momento. El documento fue revisado por los miembros de ambas sociedades para su aprobación final (AU)


Assuntos
Humanos , Esquistossomose/diagnóstico , Esquistossomose/tratamento farmacológico , Sociedades Médicas , Espanha , Consenso
7.
Enferm Infecc Microbiol Clin (Engl Ed) ; 41(8): 505-512, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37230838

RESUMO

Schistosomiasis is a highly prevalent disease, especially in immigrant populations, and is associated with significant morbidity and diagnostic delays outside endemic areas. For these reasons, the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) and the Spanish Society of Tropical Medicine and International Health (SEMTSI) have developed a joint consensus document to serve as a guide for the screening, diagnosis and treatment of this disease outside endemic areas. A panel of experts from both societies identified the main questions to be answered and developed recommendations based on the scientific evidence available at the time. The document was reviewed by the members from both societies for final approval.

8.
Int J Mol Sci ; 24(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37047384

RESUMO

Crimean-Congo haemorrhagic fever (CCHF) is a potentially lethal tick-borne viral disease with a wide distribution. In Spain, 12 human cases of CCHF have been confirmed, with four deaths. The diagnosis of CCHF is hampered by the nonspecific symptoms, the high genetic diversity of CCHFV, and the biosafety requirements to manage the virus. RT-qPCR and serological tests are used for diagnosis with limitations. Reverse-transcription loop-mediated isothermal amplification (RT-LAMP) could be an effective alternative in the diagnosis of the disease. However, none of the few RT-LAMP assays developed to date has detected different CCHFV genotypes. Here, we designed a RT-LAMP using a degenerate primer set to compensate for the variability of the CCHFV target sequence. RT-LAMP was performed in colorimetric and real-time tests on RT-qPCR-confirmed CCHF patient samples notified in Spain in 2020 and 2021. Urine from an inpatient was analysed by RT-LAMP for the first time and compared with RT-qPCR. The amplicons obtained by RT-qPCR were sequenced and African III and European V genotypes were identified. RT-LAMP amplified both genotypes and was more sensitive than RT-qPCR in urine samples. We have developed a novel, rapid, specific, and sensitive RT-LAMP test that allows the detection of different CCHFV genotypes in clinical samples. This pan-CCHFV RT-LAMP detected viral RNA for the first time in urine samples. It can be easily performed as a single-tube isothermal colorimetric method on a portable platform in real time and without the need for expensive equipment, thus bringing molecular diagnostics closer to rural or resource-poor areas, where CCHF usually occurs.


Assuntos
Vírus da Febre Hemorrágica da Crimeia-Congo , Febre Hemorrágica da Crimeia , Humanos , Vírus da Febre Hemorrágica da Crimeia-Congo/genética , Febre Hemorrágica da Crimeia/diagnóstico , Espanha , Genótipo
9.
Sensors (Basel) ; 23(8)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37112300

RESUMO

The use of inertial devices in sport has become increasingly common. The aim of this study was to examine the validity and reliability of multiple devices for measuring jump height in volleyball. The search was carried out in four databases (PubMed, Scopus, Web of Sciences and SPORTDiscus) using keywords and Boolean operators. Twenty-one studies were selected that met the established selection criteria. The studies focused on determining the validity and reliability of IMUs (52.38%), on controlling and quantifying external load (28.57%) and on describing differences between playing positions (19.05%). Indoor volleyball was the modality in which IMUs have been used the most. The most evaluated population was elite, adult and senior athletes. The IMUs were used both in training and in competition, evaluating mainly the amount of jump, the height of the jumps and some biomechanical aspects. Criteria and good validity values for jump counting are established. The reliability of the devices and the evidence is contradictory. IMUs are devices used in volleyball to count and measure vertical displacements and/or compare these measurements with the playing position, training or to determine the external load of the athletes. It has good validity measures, although inter-measurement reliability needs to be improved. Further studies are suggested to position IMUs as measuring instruments to analyze jumping and sport performance of players and teams.


Assuntos
Desempenho Atlético , Voleibol , Adulto , Humanos , Reprodutibilidade dos Testes , Atletas , Movimento , Bibliometria
10.
Materials (Basel) ; 16(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36770268

RESUMO

Calcium phosphate (CaP) with several chemical compositions and morphologies was prepared by precipitation using aqueous solutions of L-Glutamic acid (H2G) and calcium hydroxide, both mixed together with an aqueous solution (0.15 M) of phosphoric acid. Plate-shaped dicalcium phosphate dihydrate (brushite) particles were obtained and identified at a lower concentration of the solution of the reactants. The Ca/P ratio deduced by EDS was ~1, as expected. The nanoscale dimension of carbonate apatite and amorphous calcium phosphate, with variable Ca/P ratios, were revealed by X-ray diffraction (XRD) and scanning electron microscopy and energy dispersive X-ray spectroscopy analysis (SEM-EDS). They were characterized in medium and high concentrations of calcium hydroxide (0.15 M and 0.20 M). The equilibria involved in all the reactions in aqueous solution were determined. The thermodynamic calculations showed a decrease in the amount of chelate complexes with an increase in pH, being the opposite of [CaPO4-] and [CaHG+]. This fluctuation showed an evident influence on the morphology and polymorphism of CaP particles obtained under the present experimental conditions, with potential use as a biomaterial.

11.
Int J Mol Sci ; 24(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36614336

RESUMO

Loop-mediated isothermal amplification (LAMP) is the most popular technology for point-of-care testing applications due its rapid, sensitive and specific detection with simple instrumentation compared to PCR-based methods. Many systems for reading the results of LAMP amplifications exist, including real-time fluorescence detection using fluorophore-labelled probes attached to oligonucleotide sequences complementary to the target nucleic acid. This methodology allows the simultaneous detection of multiple targets (multiplexing) in one LAMP assay. A method for multiplexing LAMP is the amplification by release of quenching (DARQ) technique by using a 5'-quencher modified LAMP primer annealed to 3'-fluorophore-labelled acting as detection oligonucleotide. The main application of multiplex LAMP is the rapid and accurate diagnosis of infectious diseases, allowing differentiation of co-infecting pathogens in a single reaction. Schistosomiasis, caused among other species by Schistosoma mansoni and strongyloidiasis, caused by Strongyloides stercoralis, are the most common helminth-parasite infections worldwide with overlapping distribution areas and high possibility of coinfections in the human population. It would be of great interest to develop a duplex LAMP to detect both pathogens in the same reaction. In this study, we investigate the use of our two previously developed and well-stablished LAMP assays for S. mansoni and Strongyloides spp. DNA detection in a new duplex real-time eight-primer system based on a modified DARQ probe method that can be performed in a portable isothermal fluorimeter with minimal laboratory resources. We also applied a strategy to stabilize the duplexed DARQ-LAMP mixtures at room temperature for use as ready-to-use formats facilitating analysis in field settings as point-of-care diagnostics for schistosomiasis and strongyloidiasis.


Assuntos
Esquistossomose , Strongyloides stercoralis , Estrongiloidíase , Animais , Humanos , Schistosoma mansoni/genética , Sistemas Automatizados de Assistência Junto ao Leito , DNA de Helmintos/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Strongyloides stercoralis/genética , Oligonucleotídeos , Corantes Fluorescentes , Sensibilidade e Especificidade
12.
Materials (Basel) ; 16(2)2023 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-36676541

RESUMO

The cement manufacturing industry is one of the main greenhouse gas emission producers and also consumes a large quantity of raw materials. It is essential to reduce these emissions in order to comply with the Paris Agreement and the principles of the circular economy. The objective of this research was to develop different types of cement clinker blends using industrial waste and innovative design to produce low-energy cement. Several types of waste have been studied as alternative raw materials. Their main characteristics have been analyzed via X-ray fluorescence (XRF), X-ray diffraction (XRD), Attenuated total reflectance Fourier trans-form infrared spectroscopy (ATR-FTIR), thermal analysis (TG-DTG-DSC) and scanning electron microscopy and energy dispersive X-ray spectroscopy analysis (SEM-EDS). The results obtained from the experimental work carried out in this research focused on the study of crude blends for low-energy cement created from industrial waste. The effect of the addition of different industrial waste types, as a substitution for raw materials, in the production of low-energy cement with high dicalcium silicate content has been investigated. Thus, the dosage design has been performed using modified Bogue equations and quality indexes (LSF, AM, and SM). The calculations of both the modified Bogue equations and quality indexes necessitate knowledge of the weight percentages of CaO, SiO2, Al2O3, and Fe2O3, determined via XRF. In this theoretical design of the different blends, it has been established that a dicalcium silicate ratio of 60-65 wt % and an LSF of 78-83% as the limit are values common to all of them. The calculation basis for the crude blends has been based on calcined materials. Therefore, the chemical composition was established, following this premise. Thus, it was possible to develop cement clinker blends with compositions of 50 wt % and 100 wt % using industrial wastes. This research has shown that the clinkerization process is one of the main options for the valorization of waste and its consideration for inclusion as a raw material within the circularity of the cement industry's production process. Thus, waste is used as a raw material for the production of a more useful substance, taking into account the fundamental principles of the circular economy.

13.
Rev. méd. Maule ; 37(2): 70-75, dic. 2022. ilus
Artigo em Espanhol | LILACS | ID: biblio-1428534

RESUMO

SPeripheral sympathectomy is a procedure which has shown high rates of decreasing ischemic pain, recover functionality and wound healing, preventing the progression of the disease and further complications. We present a female patient with severe Raynaud´s phenomenon secondary to localized cutaneous systemic sclerosis complicated who presented digital ulcer treated with a sympathectomy of the radial and ulnar artery at the wrist level, undergoing post-operative follow-up.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Doença de Raynaud/cirurgia , Simpatectomia/métodos , Artéria Ulnar/inervação , Osteomielite , Doença de Raynaud/etiologia , Fluxo Sanguíneo Regional/fisiologia , Esclerodermia Localizada , Escleroderma Sistêmico , Seguimentos , Artéria Radial/inervação
14.
Int J Mol Sci ; 23(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36430586

RESUMO

Since the onset of the COVID-19 pandemic, over 610 million cases have been diagnosed and it has caused over 6.5 million deaths worldwide. The crisis has forced the scientific community to develop tools for disease control and management at a pace never seen before. The control of the pandemic heavily relies in the use of fast and accurate diagnostics, that allow testing at a large scale. The gold standard diagnosis of viral infections is the RT-qPCR. Although it provides consistent and reliable results, it is hampered by its limited throughput and technical requirements. Here, we discuss the main approaches to rapid and point-of-care diagnostics based on RT-qPCR and isothermal amplification diagnostics. We describe the main COVID-19 molecular diagnostic tests approved for self-testing at home or for point-of-care testing and compare the available options. We define the influence of specimen selection and processing, the clinical validation, result readout improvement strategies, the combination with CRISPR-based detection and the diagnostic challenge posed by SARS-CoV-2 variants for different isothermal amplification techniques, with a particular focus on LAMP and recombinase polymerase amplification (RPA). Finally, we try to shed light on the effect the improvement in molecular diagnostics during the COVID-19 pandemic could have in the future of other infectious diseases.


Assuntos
COVID-19 , Ácidos Nucleicos , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos
15.
Materials (Basel) ; 15(16)2022 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-36013668

RESUMO

In the agricultural sector, companies involved in the production of plastic greenhouses are currently searching for a suitable covering adapted for every climate in the world. For this purpose, this research work has determined the chemical, radiometric and mechanical properties of 53 polymeric films samples from Europe and South America. The chemical tests carried out with these samples were elemental analysis (C, H and N) and FT-IR spectrometry. The radiometric properties here studied were the transmission, absorption and reflection coefficients along the spectrum between 300 and 1100 nm. For the mechanical properties, tensile strength, tear strength and dart impact strength, tests were carried out. Finally, all these data were collected, and a multivariate statistical analysis was carried out using the SPSS statistical to group the samples into statistical groups adapted to specific climatic regions. The elemental analysis and FT-IR spectrometry allowed group the samples into nine groups. The samples were grouped according to their chemical (elemental analysis), radiometric and mechanical properties by multivariate analysis. The dendrogram separated five very different groups in terms of number of samples. These groups have specific chemical, radiometric and mechanical characteristics that separate them from the rest. These groups make it possible to narrow down the applications and correlate with the radiometric properties to see in which geographical area of the world they are most effective in increasing yields and achieving higher quality production.

16.
Biosensors (Basel) ; 12(6)2022 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-35735571

RESUMO

Nucleic acid amplification diagnostics offer outstanding features of sensitivity and specificity. However, they still lack speed and robustness, require extensive infrastructure, and are neither affordable nor user-friendly. Thus, they have not been extensively applied in point-of-care diagnostics, particularly in low-resource settings. In this work, we have combined the loop-mediated isothermal amplification (LAMP) technology with a handheld portable device (SMART-LAMP) developed to perform real-time isothermal nucleic acid amplification reactions, based on simple colorimetric measurements, all of which are Bluetooth-controlled by a dedicated smartphone app. We have validated its diagnostic utility regarding different infectious diseases, including Schistosomiasis, Strongyloidiasis, and COVID-19, and analyzed clinical samples from suspected COVID-19 patients. Finally, we have proved that the combination of long-term stabilized LAMP master mixes, stored and transported at room temperature with our developed SMART-LAMP device, provides an improvement towards true point-of-care diagnosis of infectious diseases in settings with limited infrastructure. Our proposal could be easily adapted to the diagnosis of other infectious diseases.


Assuntos
COVID-19 , Doenças Transmissíveis , Ácidos Nucleicos , COVID-19/diagnóstico , Colorimetria , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Smartphone
18.
Trop Med Int Health ; 27(8): 686-695, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35653502

RESUMO

OBJECTIVES: Loa loa and Mansonella perstans are two very common filarial species in Africa. Although microscopy is the traditional diagnostic method for human filariasis, several polymerase chain reaction (PCR) methods have emerged as an alternative approach for identifying filarial parasites. The aim of this study is to compare three molecular methods and decide which is the most suitable for diagnosing human loiasis and mansonellosis in non-endemic regions using dried blood spot (DBS) as a medium for sample collection and storage. METHODS: A total of 100 DBS samples, with their corresponding thin and thick blood smears, were selected for this study. Microscopy was used as the reference method to diagnose and calculate the microfilaraemia. Filarial DNA was extracted using the saponin/Chelex method and the DNA isolated was assayed by Filaria-real time-PCR, filaria-nested PCR, and cytochrome oxidase I PCR. All PCR products were subsequently purified and sequenced. The statistical values for each molecular test were calculated and compared. RESULTS: Overall, 64 samples were identified as negative by all tests and a further 36 samples were positive by at least one of the methods used. The sensitivity and specificity were similar for the different molecular methods, all of which demonstrated good agreement with microscopy. CONCLUSIONS: Based on this study, and from a practical point of view (single and short amplification round), the optimal technique for diagnosing filarial infection in non-endemic regions is filaria-real time-PCR, which presents high sensitivity and specificity and is also able to detect a wide range of human filariae.


Assuntos
Loíase , Mansonelose , Animais , Humanos , Loa/genética , Loíase/diagnóstico , Loíase/parasitologia , Mansonella/genética , Mansonelose/diagnóstico , Mansonelose/parasitologia , Reação em Cadeia da Polimerase
19.
Diagnostics (Basel) ; 12(5)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35626235

RESUMO

Loiasis, caused by the filarial nematode Loa loa, is endemic in Central and West Africa. Loa loa has been associated with severe adverse reactions in high Loa-infected individuals receiving ivermectin during mass drug administration programs for the control of onchocerciasis and lymphatic filariasis. Diagnosis of loiasis still depends on microscopy in blood samples, but this is not effective for large-scale surveys. New diagnostics methods for loiasis are urgently needed. Previously, we developed a colorimetric high-sensitive and species-specific LAMP for Loa loa DNA detection. Here, we evaluate it in a set of 100 field-collected clinical samples stored as dried blood spots. In addition, Loa loa-LAMP was also evaluated in real-time testing and compared with microscopy and a specific PCR/nested PCR. A simple saponin/Chelex-based method was used to extract DNA. Colorimetric and real-time LAMP assays detected more samples with microscopy-confirmed Loa loa and Loa loa/Mansonella perstans mixed infections than PCR/nested-PCR. Samples with the highest Loa loa microfilariae counts were amplified faster in real-time LAMP assays. Our Loa loa-LAMP could be a promising molecular tool for the easy, rapid and accurate screening of patients for loiasis in endemic areas with low-resource settings. The real-time testing (feasible in a handheld device) could be very useful to rule out high-microfilariae loads in infected patients.

20.
Materials (Basel) ; 15(2)2022 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-35057297

RESUMO

A deposit of raw kaolin, located in West Andalusia (Spain), was studied in this work using a representative sample. The methods of characterization were X-ray diffraction (XRD), X-ray fluorescence (XRF), particle size analysis by sieving and sedimentation, and thermal analysis. The ceramic properties were determined. A sample of commercial kaolin from Burela (Lugo, Spain), with applications in the ceramic industry, was used in some determinations for comparison purposes. The kaolin deposit has been produced by alteration of feldspar-rich rocks. This raw kaolin was applied as an additive in local manufactures of ceramics and refractories. However, there is not previous studies concerning its characteristics and firing properties. Thus, the meaning of this investigation was to conduct a scientific study on this subject and to evaluate the possibilities of application. The raw kaolin was washed for the beneficiation of the rock using water to increase the kaolinite content of the resultant material. The results indicated that the kaolinite content of the raw material was 20 wt % as determined by XRD, showing ~23 wt % of particles lower than 63 µm. The kaolinite content of the fraction lower than 63 µm was 50 wt %. Thus, an improvement of the kaolinite content of this raw kaolin was produced by wet separation. However, the kaolin was considered as a waste kaolin, with microcline, muscovite and quartz identified by XRD. Thermal analyses by Thermo-Dilatometry (TD), Differential Thermal Analysis (DTA) and Thermo-Gravimetry (TG) allowed observe kaolinite thermal decomposition, quartz phase transition and sintering effects. Pressed samples of this raw kaolin, the fraction lower than 63 µm obtained by water washing and the raw kaolin ground using a hammer mill were fired at several temperatures in the range 1000-1500 °C for 2 h. The ceramic properties of all these samples were determined and compared. The results showed the progressive linear firing shrinkage by sintering in these samples, with a maximum value of ~9% in the fraction lower than 63 µm. In general, water absorption capacity of the fired samples showed a decrease from ~18-20% at 1050 °C up to almost zero after firing at 1300 °C, followed by an increase of the experimental values. The open porosity was almost zero after firing at 1350 °C for 2 h and the bulk density reached a maximum value of 2.40 g/cm3 as observed in the ground raw kaolin sample. The XRD examination of fired samples indicated that they are composed by mullite, from kaolinite thermal decomposition, and quartz, present in the raw sample, as main crystalline phases besides a vitreous phase. Fully-densified or vitrified materials were obtained by firing at 1300-1350 °C for 2 h. In a second step of this research, it was examined the promising application of the previous study to increase the amount of mullite by incorporation of alumina (α-alumina) to this kaolin sample. Firing of mixtures, prepared using this kaolin and α-alumina under wet processing conditions, produced the increase of mullite in relative proportion by reaction sintering at temperatures higher than 1500 °C for 2 h. Consequently, a mullite refractory can be prepared using this kaolin. This processing of high-alumina refractories is favoured by a previous size separation, which increases the kaolinite content, or better a grinding treatment of the raw kaolin.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...